Lesson 2/Learning Event 3
will record the maintenance accomplished on the DA Form 3254-R and return it
to the originating laboratory within five working days after maintenance is
accomplished.
NOTE:
The AOAP pressure-sensitive labels will be used on components going
to a maintenance/overhaul facility. Two labels will be affixed to
opposite sides of the component and two on the opposite sides of the
outside of the shipping container. These labels will be supplied by
the laboratory along with the DA Form 3254-R.
To summarize--
1.
Remember to follow TB 43-0210.
2.
The AOAP is a very effective maintenance diagnostic tool.
It is not a
substitute for good maintenance.
3.
For equipment under warranty, follow manufacturer's instructions for
oil/filter changes.
4.
Keep sampling supplies and forms on hand.
5.
Keep up your good maintenance.
70