TM
5-811-1/AFJMAN
32-1080
American National Standard for Switchgear-AC High-Voltage Circuit Break-
C37.06-1987
ers Rated on a Symmetrical Current Basis-Preferred Ratings and Related
Required Capabilities
Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures
C37.13-1979
Standard for Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
C37.20.1-1987
C37.20.2-1987
Standard for Metal-Clad and Station-Type Cubicle Switchgear
C37.20.3-1987
Standard for Metal-Enclosed Interrupter Switchgear
Definitions and Requirements for High-Voltage Air Switches, Insulators, and
C37.30-1971
Bus Supports
Schedules of Preferred Ratings, Manufacturing Specifications, and Application
C37.32-1972
Guide for High-Voltage Air Switches, Bus Supports, and Switch Accessories
Service Conditions and Definitions for High-Voltage Fuses, Distribution
C37.40-1981
Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Acces-
sories
IEEE Guide for Application, Operation, and Maintenance of High-Voltage
C37.48-1987
Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting
Switches, and Accessories
Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Auto-
C37.63-1984
matic Line Sectionalizers for AC Systems
Relays and Relay Systems Associated with Electric Power Apparatus
C37.90-1978
General Requirements for Liquid-Immersed Distribution, Power, and Regulat-
C57.12.00-1987
ing Transformers (ANSI)
Terminology for Power and Distribution Transformers (ANSI)
C57.12.80-1978
Requirements for Instrument Transformers (ANSI)
C57.13-1978
Requirements, Terminology, and Test Code for Step-Voltage and Induction-
C57.15-1986
Voltage Regulators (ANSI)
Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Distribu-
C57.91-1981
tion Transformers Rated 500 kVA and Less with 65 C or 55 C Average
Winding Rise (ANSI)
Guide for Loading Mineral-Oil-Immersed Power Transformers Up to and
C57.92-1981
Including 100 MVA with 55 C or 65 C Average Winding Rise (ANSI)
Guide for Loading Dry-Type Distribution and Power Transformers (ANSI)
C57.96-1989
C57.98-1986
Loss Evaluation Guide for Power Transformers and Reactors
C57.120-1991
Standard for Gapped Silicon-Carbide Surge Arresters for AC Power Circuits
C62.1-1989
(ANSI)
Guide for the Application of Gapped Silicon-Carbide Surge Arresters for
C62.2-1987
Alternating Current Systems (ANSI)
Standard for Metal-Oxide Surge Arresters for AC Power Circuits (ANSI)
C62.11-1987
Standard for Shunt Power Capacitors
18-1980
General Requirements and Test Procedures for Outdoor Apparatus Bushings
21-1976
Requirements, Terminology, and Test Procedure for Neutral Grounding Devices
32-1972, R 1984
Test Procedures and Requirements for High-Voltage AC Cable Terminations
48-1975
A-4